Viewing Issue Advanced Details
ID | Category [?] | Severity [?] | Reproducibility | Date Submitted | Last Update |
---|---|---|---|---|---|
08363 | Core | Major | Always | Jun 25, 2022, 16:47 | 18 days ago |
Tester | bellet | View Status | Public | Platform | MAME (Self-compiled) |
Assigned To | AJR | Resolution | Fixed | OS | Linux (64-bit) |
Status [?] | Resolved | Driver | |||
Version | 0.244 | Fixed in Version | 0.271 | Build | 64-bit |
Fixed in Git Commit | ab28659 | Github Pull Request # | |||
Summary | 08363: to9: Regression in cartridge selection | ||||
Description |
I think commit b94b14469e8 introduced a regression in the TO9 machine cartridge selection. The first 4 slots only should redirect to the cartridge region. Next slots, starting from 4 and higher should refer to the maincpu region instead. The bank switching for the TO9 is in function to9_state::to9_update_cart_bank(). In MACHINE_RESET_MEMBER( to9_state, to9 ), something like that maybe: - m_cartbank->configure_entries( 0, 12, cartmem, 0x4000 ); + m_cartbank->configure_entries( 0, 4, cartmem, 0x4000 ); + m_cartbank->configure_entries( 4, 8, mem + 0x10000, 0x4000 ); |
||||
Steps To Reproduce | |||||
Additional Information | |||||
Github Commit | |||||
Flags | |||||
Regression Version | |||||
Affected Sets / Systems | to9 | ||||
Attached Files
|
|||||
Relationships
There are no relationship linked to this issue. |
Notes
0
There are no notes attached to this issue. |